探讨急性缺血性卒中患者“一站式CT”检查的辐射安全问题

荆利娜,高培毅,林燕,薛静,马丽,王效春,隋滨滨,王辉,沈宓   

  1. 北京市首都医科大学附属北京天坛医院放射科北京市神经外科研究所神经放射科
  • 收稿日期:2010-10-25 修回日期:2010-09-25 出版日期:2011-09-20 发布日期:2011-09-20
  • 通讯作者: 高培毅

Radiation Dose from “One-Stop-Shop” Computed Tomography Imaging for AcuteIschemic Stroke

JING Li-Na, GAO Pei-Yi, LIN Yan, et al   

  • Received:2010-10-25 Revised:2010-09-25 Online:2011-09-20 Published:2011-09-20
  • Contact: GAO Pei-Yi

摘要: 目的 评价急性缺血性卒中患者“一站式CT”检查的辐射剂量。方法 34例急性缺血性卒中患者(发病时间在3~9 h)进行了“一站式CT”检查。“一站式CT”检查包括CT平扫(un-enhanced CT head,NECT)、CT灌注(CT perfusion,CTP)及CT血管成像(CT angiography,CTA),记录扫描时机器显示的容积CT剂量指数(volume CT dose index,CTDIvol)及剂量长度乘积(dose-length product,DLP),DLP乘以头部的有效剂量系数得到有效剂量。结果 入组患者“一站式C T”检查的平均C T D I v o l为8 4 5.9 6±2 3.7 8 m G y,平均D L P为2748.92±129.25 mGy,总有效剂量范围5.96~7.81 mSv,平均为6.32±0.03 mSv,其中NECT有效剂量为2.14±0.27 mSv,CTP有效剂量为3.51 mSv,CTA有效剂量为0.67±0.07 mSv。2例患者CT平扫时出现移动伪影,补扫后导致此2例患者有效剂量较其他患者略高,分别为7.81 mSv、6.71 mSv。结论 急性脑缺血性卒中患者“一站式CT”检查参数设置符合美国食品及药物管理局推荐标准,安全、合理,并且能够指导急性缺血性卒中患者进行溶栓治疗。

关键词: 脑梗死; 辐射剂量; 体层摄影术; X线计算机

Abstract: Objective To determine the radiation dose delivered during “one-stop-shop” computedtomography(CT) imaging for acute ischemic stroke.Methods "One-stop shop" CT examination was performed in 34 patients with symptoms ofacute stroke less than 9 hours. The Protocol includes an un-enhanced CT(NECT) head, CTperfusion(CTP), and CT angiography(CTA) from cranial base to vertex. The weighted volumeCT dose index(CTDIvol) and dose-length products(DLP) were recorded during the CT scanning.Effective doses for each examination were calculated using the DLP and normalized values ofeffective dose per DLP appropriate for the head regions imaged.Results In 34 patients, mean CTDIvol was 845.96±23.78 mGy; mean DLP was2748.92±129.25 mGy×cm; the effective doses ranged from 5.96 to 7.81 mSv, mean effective dosewas 6.32±0.03 mSv. Largest contribution to effective dose was the CTP with a mean effectivedose of 3.51 mSv. Mean effective doses for the NECT, CTA were 2.14±0.27 mSv, 0.67±0.07 mSv,respectively.Conclusion Parameters of “one-stop-shop” CT comply with the standards that American food anddrug administration recommends, and the radiation doses are reasonable, furthermore, “one-stopshop”CT plays a key role in the management of the patients with acute ischemic stroke.

Key words: Brain infarction; Radiation dosage; Tomography; x-ray computed